eXtremeRAID 3000Installation GuideDB11-000033-00 First Edition08P5525

Strany 3 - 408.433.8000

About This ManualThis installation guide covers hardware set-up and configuration procedures necessary for the installation of a Mylex eXtremeRAID 300

Strany 4 - Declaration of Conformity

ConventionsThroughout the manual, the following conventions are used to describe user interaction with the product:prompt This style of type indicates

Strany 5

Manual No. DB11-000033-00 iiiContentsChapter 1IntroductionProduct Description ...

Strany 6 - Community of Europe

iv eXtremeRAID 3000 Installation GuideOperating System Device Drivers ...3-5Global Array Manager (G

Strany 7

Manual No. DB11-000033-00 vAppendix DPCI Hot PlugIntroduction ...

Strany 8 - Copyright Notice

vi eXtremeRAID 3000 Installation Guide

Strany 9 - Trademark Acknowledgments

Manual No. DB11-000033-00 1-1Chapter 1IntroductionThis chapter describes:• The eXtremeRAID™ 3000 controller• Standard package contents• User supplie

Strany 10

Product Description1-2 eXtremeRAID 3000 Installation GuideController FeaturesFeatures of the eXtremeRAID 3000 controller include:• Two Q-Logic ISP 210

Strany 11 - About This Manual

IntroductionManual No. DB11-000033-00 1-3Channel Capabilities• 126 physical devices per Fibre loop channel• 15 physical devices per SCSI channelContro

Strany 12 -  WARNING

Electromagnetic Compatibility NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This

Strany 13 - Contents

Standard Package Contents1-4 eXtremeRAID 3000 Installation GuideStandard Package ContentsThe following items are supplied with the standard shipping p

Strany 14 - Error Messages

IntroductionManual No. DB11-000033-00 1-5User-supplied Items The following user-supplied items are required to perform this installation:SCSI• IBM-PC™

Strany 15 - PCI Hot Plug

User-supplied Items1-6 eXtremeRAID 3000 Installation Guide

Strany 16

Manual No. DB11-000033-00 2-1Chapter 2InstallationThis chapter describes:• Before you begin• Safety Considerations• Installation Checklist• Connectors

Strany 17 - Introduction

Before You Begin2-2 eXtremeRAID 3000 Installation GuideBefore You BeginInstalling the eXtremeRAID 3000 Fibre Channel RAID controller is no more diffic

Strany 18

InstallationManual No. DB11-000033-00 2-3Safety ConsiderationsBe sure to observe the following precautions before beginning the controller installatio

Strany 19 - Operating System Support

Installation Checklist2-4 eXtremeRAID 3000 Installation GuideInstallation ChecklistGET READY☛ NoteIt is recommended that you wear a grounded wrist str

Strany 20 - Standard Package Contents

InstallationManual No. DB11-000033-00 2-513. ____ Safety check the installation.☛ NoteReview Figure 2-1, Figure 2-2, Figure 2-3 and Table 2-1 to get f

Strany 21 - User-supplied Items

Connectors, Jumpers and LEDs2-6 eXtremeRAID 3000 Installation GuideConnectors, Jumpers and LEDsThere are two Fibre Loop connectors and one internal Ul

Strany 22

InstallationManual No. DB11-000033-00 2-7 Figure 2-1. eXtremeRAID 3000 Controller with ConnectorsFigure 2-2. eXtremeRAID 3000 Controller with Jumpe

Strany 23 - Installation

Interference-Causing Equipment Regulations.Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur

Strany 24

Connectors, Jumpers and LEDs2-8 eXtremeRAID 3000 Installation GuideFigure 2-3. eXtremeRAID 3000 Controller with LEDs (back side)3- Fibre Activity1- SC

Strany 25

InstallationManual No. DB11-000033-00 2-9Follow these installation steps:1. Choose any available 32 bit or 64 bit PCI slot as shown in Figure 2-4. Fig

Strany 26 - Installation Checklist

Connectors, Jumpers and LEDs2-10 eXtremeRAID 3000 Installation Guide3. Remove the eXtremeRAID 3000 controller from the anti-static bag as shown in Fig

Strany 27 - Manual No. DB11-000033-00 2-5

InstallationManual No. DB11-000033-00 2-115. Connect the SCSI cables from the internal disk drives to the SCSI connector on the eXtremeRAID 3000 contr

Strany 28 - Connectors, Jumpers and LEDs

Connectors, Jumpers and LEDs2-12 eXtremeRAID 3000 Installation GuideSCSI TerminationEach end of a SCSI bus must be terminated to maintain proper volta

Strany 29 - Manual No. DB11-000033-00 2-7

InstallationManual No. DB11-000033-00 2-13SCSI CablingThe controller supports one internal Ultra2 SCSI channel which can support up to 15 SCSI devices

Strany 30

Connectors, Jumpers and LEDs2-14 eXtremeRAID 3000 Installation GuideSCSI Drive PreparationTo prepare the drives for installation, follow these steps:1

Strany 31 - 32 bit PCI slots

InstallationManual No. DB11-000033-00 2-15Figure 2-9. Fibre External Drive Configuration Fibre CablingThe eXtremeRAID 3000 controller supports two Fib

Strany 32 - Black Handle

Connectors, Jumpers and LEDs2-16 eXtremeRAID 3000 Installation GuideFibre Connectors, ExternalThe external Fibre connectors are on the controller’s Hi

Strany 33

InstallationManual No. DB11-000033-00 2-17Fibre Drive PreparationTo prepare the drives for installation, follow these steps:1. Set up your Fibre Chann

Strany 34 - SCSI Termination

Declaration of ConformityPer FCC Part 2, Section 2.1077(a)Manufacturer’s Name: LSI Logic Corporation Manufacturer’s Address:North American Headquarter

Strany 35 - SCSI Cabling

Connectors, Jumpers and LEDs2-18 eXtremeRAID 3000 Installation Guide

Strany 36

Manual No. DB11-000033-00 3-1Chapter 3Controller Start-upThis chapter describes:•BIOS Options• BIOS Configuration Utility (RAID EzAssist)• Operating S

Strany 37 - Fibre Cabling

BIOS Options3-2 eXtremeRAID 3000 Installation Guideand the Drive geometry parameters.

Strany 38 - Fibre Connectors, External

Controller Start-upManual No. DB11-000033-00 3-3Setting BIOS OptionsThe available BIOS options are:• BIOS disabled/enabled• CD-ROM boot disabled/disab

Strany 39 - Fibre Drive Preparation

BIOS Options3-4 eXtremeRAID 3000 Installation GuideEnable 8GByte or 2GByte DrivesThis setting affects how the BIOS reads the disk drives for the boot

Strany 40

Controller Start-upManual No. DB11-000033-00 3-5☛ NoteIn the event that the RAID controller needs to be replaced, the current drive geometry will be r

Strany 41 - Controller Start-up

Global Array Manager (GAM) Client3-6 eXtremeRAID 3000 Installation GuideGlobal Array Manager (GAM) ClientThe controller can be configured using Global

Strany 42 - BIOS Options

Manual No. DB11-000033-00 A-1 Appendix AMemory Module andBattery Backup UnitFigure A-1. BDIMM ModuleProduct Description The Battery Dual Inline Memory

Strany 43 - Setting BIOS Options

BDIMM OperationA-2 eXtremeRAID 3000 Installation Guide BDIMM Operation This BDIMM consists of 32MB, 64MB, 128MB of ECC1 SDRAM cache memory, a lithium

Strany 44

Memory Module and Battery Backup UnitManual No. DB11-000033-00 A-3 Maintenance No maintenance is required. It is recommended that the BDIMM charge lev

Strany 45 - Operating System

Declaration of ConformityPer 89\336\EECResponsible PartyName:LSI Logic Corporation Address:North American HeadquartersMilpitas, CAU.S.A.hereby declare

Strany 46 - In Case of Problems

BDIMM Functional DescriptionA-4 eXtremeRAID 3000 Installation Guide Status Indication Battery status can be checked, and the battery can be reconditio

Strany 47

Memory Module and Battery Backup UnitManual No. DB11-000033-00 A-5 BDIMM Specifications On-board Battery Electrical Properties• One Lithium-Ion cell,

Strany 48 - BDIMM Operation

BDIMM SpecificationsA-6 eXtremeRAID 3000 Installation Guide

Strany 49

Manual No. DB11-000033-00 B-1Appendix BeXtremeRAID 3000SpecificationsGeneral Hardware SpecificationseXtremeRAID 3000Controller eXtremeRAID 3000CPU Str

Strany 50 - Battery and Charge Circuit

Environmental SpecificationsB-2 eXtremeRAID 3000 Installation GuideEnvironmental Specifications Controller eXtremeRAID 3000Temperature Operating 0°C t

Strany 51 - BDIMM Specifications

Manual No. DB11-000033-00 C-1Appendix CeXtremeRAID 3000Error Messages☛ NoteThe firmware you are using may have these messages turned off. However, the

Strany 52

Installation AbortC-2 eXtremeRAID 3000 Installation GuideDuring the initialization, if the firmware fails to respond to the BIOS inquiry within two mi

Strany 53 - Specifications

eXtremeRAID 3000 Error MessagesManual No. DB11-000033-00 C-3EzAssist Configuration Utility User Reference Guide or RAID EzAssist Configuration Utility

Strany 54 - Environmental Specifications

System Reboot or Power DownC-4 eXtremeRAID 3000 Installation Guide

Strany 55

Manual No. DB11-000033-00 D-1Appendix DPCI Hot PlugIntroductionPCI Hot Plug is a feature that allows a PCI card to be replaced while the host system i

Strany 56 - Installation Abort

Community of EuropeCE mark is rated for the eXtremeRAID 3000 as follows: CISPR 22 Radiated EmissionEN55022, Generic immunity standard for the followi

Strany 57 - System Reboot or Power Down

ImplementationD-2 eXtremeRAID 3000 Installation Guide• odineb.nlm –This is a module combining the Open Data-link interface and the Novell Event Bus (N

Strany 58

PCI Hot PlugManual No. DB11-000033-00 D-3Windows NTWindows NT requires additional software from the vendor who makes the system. Since this software i

Strany 59

ImplementationD-4 eXtremeRAID 3000 Installation GuidePlease refer to the Windows XP or .NET 32-bit documentation for instructions on how to use the PC

Strany 60 - Implementation

Manual No. DB11-000033-00 E-1Appendix EEnclosure ManagementIntroductionMylex’s eXtremeRAID controllers support the industry standard enclosure managem

Strany 61

SAF-TEE-2 eXtremeRAID 3000 Installation GuideFibre Channel CabinetYou will need to use a Fibre, High Speed Serial Data Connector (HSSDC), cable to con

Strany 62

Manual No. DB11-000033-00 G-1GlossaryAcceleRAID™The AcceleRAID family features high performance, cost effective Ultra SCSI/Ultra2 SCSI LVD and Ultra 1

Strany 63

G-2 eXtremeRAID 3000 Installation GuideAutomatic RebuildMylex controllers provide automatic rebuild capabilities in the event of a physical disk drive

Strany 64 - Fibre Channel Cabinet

GlossaryManual No. DB11-000033-00 G-3BusA set of conductors that connect the functional units in a computer and are the channels through which data is

Strany 65

G-4 eXtremeRAID 3000 Installation GuideSCSI bus on a disk array controller. Each disk array controller provides at least one channel.Conservative Cach

Strany 66

GlossaryManual No. DB11-000033-00 G-5Disk ArrayA collection of disks from one or more commonly accessible disk systems. Disk arrays, also known as RAI

Strany 67 - Manual No. DB11-000033-00 G-3

Underwriters Laboratories Statement and Warning

Strany 68

G-6 eXtremeRAID 3000 Installation GuideECCError Correcting Code, a method of generating redundant information which can be used to detect and correct

Strany 69 - Manual No. DB11-000033-00 G-5

GlossaryManual No. DB11-000033-00 G-7FailbackRestoring a failed system component’s share of a load to a replacement component.FailoverA mode of operat

Strany 70

G-8 eXtremeRAID 3000 Installation GuideGigabyte230 (1,073,741,824) bytes. Abbreviated as G or GB.Global Array Manager (GAM)A Mylex RAID management uti

Strany 71 - Manual No. DB11-000033-00 G-7

GlossaryManual No. DB11-000033-00 G-9controller to “rebuild” the data on the new drive, all without interrupting system operations. Once the rebuild i

Strany 72

G-10 eXtremeRAID 3000 Installation GuideI/OInput/Output, the transmission of information between an external source and the computer.I/O BusAny path u

Strany 73 - Manual No. DB11-000033-00 G-9

GlossaryManual No. DB11-000033-00 G-11Logical Drive StatesA logical (system) drive can be Online, Critical, or Offline. Notice that the term “online”

Strany 74

G-12 eXtremeRAID 3000 Installation GuideMirroringRefers to the complete duplication of data on one disk drive to another disk drive, this duplication

Strany 75

GlossaryManual No. DB11-000033-00 G-13OfflineA Logical Drive is in an “offline” state if no data can be read from it or written to it. Offline does no

Strany 76 - Narrow SCSI

G-14 eXtremeRAID 3000 Installation GuidePhysical DeviceAny device connected to some kind of hardware. For example, SCSI disk, fibre disk, network disk

Strany 77

GlossaryManual No. DB11-000033-00 G-15RAID LevelsMylex disk array controllers support four RAID Advisory Board approved (RAID 0, RAID 1, RAID 3, and R

Strany 78

Proprietary Rights NoticeThis document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used b

Strany 79 - RAID Levels

G-16 eXtremeRAID 3000 Installation GuideRAID MigrationA feature in RAID subsystems that allows for changing a RAID level to another level without powe

Strany 80

GlossaryManual No. DB11-000033-00 G-17enclosure itself is treated as simply another device on the SCSI bus. Many other leading server, storage, and RA

Strany 81 - SCSI Drive States

G-18 eXtremeRAID 3000 Installation GuideOffline: A SCSI disk drive is in a “offline” state if it is not present, if it is present but not powered on,

Strany 82

GlossaryManual No. DB11-000033-00 G-19reported, conservative cache is enabled and all system drives are switched to write-through cache. Primarily use

Strany 83 - SAME DAC960 controller

G-20 eXtremeRAID 3000 Installation GuideTo use the standby rebuild feature, you should always maintain a standby SCSI disk in your system. When a disk

Strany 84 - Striping

GlossaryManual No. DB11-000033-00 G-21drive 1, block 2 on SCSI drive 2, block 3 on SCSI drive 3, block 4 on SCSI drive 1, block 5 on SCSI drive 2, and

Strany 85

G-22 eXtremeRAID 3000 Installation GuideUltra SCSI (Fast 20 SCSI)A high performance SCSI protocol that has a bus speed of 20 Megabytes per second in t

Strany 86

LSI LOGIC CORPORATIONSOFTWARE LICENSE AND WARRANTY POLICYLimited WarrantyLSI warrants to the original purchaser of the product enclosed herein(“Custom

Strany 87 - LSI LOGIC CORPORATION

with LSI’s instructions and the terms of this Agreement, shippingcosts to be borne by LSI, and (c) Customer has provided proof ofpurchase price and da

Strany 88

is a part of the Product (“LSI Software”) solely as part of the Productincorporated into the OEM Products that and not on a standalonebasis. Customer

Strany 89

Trademark AcknowledgmentsLSI Logic, the LSI Logic logo, MORE, Mylex, and SANmapping are trademarks or registered trademarks of LSI Logic Corporation.

Strany 90

Manual No. DB11-000033-0008P5525LSI Logic CorporationNorth American HeadquartersMilpitas, CA408.433.8000